Exhaust System
I WARNING I
Carbon
monoxide gas is deadly! Carbon monoxide is a dangerous gas that can cause
unconsciousness and is potentially lethal. Some
of
the symptoms or signs of carbon
monoxide inhalation or poisoning are listed below.
• Dizziness
• Vomiting
• Intense Headache
• Muscular Twitching
• Weakness and Sleepiness
• Throbbing in Temples
The generator
must have its own separate exhaust installed
so
that the entry of raw water into the engine's
exhaust manifold and cylinders is prevented while the engine
is
not running, or while the vessel is under
sailor
power in which case the vessel
may
experience heeling, backing down from following seas, or any
other condition. Special attention
must be taken to make certain the exhaust system is secure, tight and
free
of
leaks.
The raw water supply through-hull sea cock fittings
must be
of
the flush-hull type. High-speed scoop
types or weedless scoop types must not be used, as they tend to encourage siphoning.
When a water lift type exhaust system is used, the
exhaust muflIer should be mounted
as
close
to
the
engine
as
practical. The exhaust discharge should
always drop downward into the exhaust muflIer.
Loops
in
the exhaust hose between the water-injected
exhaust elbow and the water lift muflIer should be
avoided,
as
these will trap and hold water.
For installations where the exhaust manifoldlwater-
injected exhaust elbow is within 8 inches or below
the vessel's water line, provisions
must be made to
install a siphon-break or a vent in the raw water
supply hose to the water-injected exhaust elbow.
This stops the flow
of
raw water that runs through
the raw water cooling system from filling the
exhaust and engine cylinders when the engine
is
shut
down. This raw water supply hose
must be looped
above the water line and the siphon-break or vent
must always be above the water line during all angles
of vessel operation
to
prevent siphoning. The vent,
when used, must have its vent hose or tube routed
so
it can remain above the water line and empty
of
water when the engine
is
shut down. This allows air
to enter through this vent to prevent siphoning.
WESTERBEKE
GENERATORS
16
Wlnl1l1
IUR
...
tn
LIlt
Komentáře k této Příručce